Introduction: The equipment records bioelectricity activity of nerve muscle for determining its function state, which combines with nerve conduction speed, to give patient an auxiliary diagnosis.Checking contents: EMG(electromygram), MCS(motor nerve conductor velocity), SCS(sensory nerve conductor velocity), F wave, Hreflex, RNS(repetitive nerve stimulation), Blink Reflex, VEP(visual evoked potential), BAEP(brainstem auditory evoked potential), SEP(somatosensory evoked potential), etc.
Features:
1.ProfessionalEMG/EP operation platform and perfect test items, complete each test in the shortest time.
2.Neuro and muscle navigation system, convenient in selecting test part.
3.Powerful normal values system, contrast with normal data automatically.
4.Flexible software design, configure system parameters according to requirements.
5.High-speed data collection, electromagnetic interference suppression, Photoelectric isolation and low noise.
6.Integrative hardware system, compact in configuration and easy in moving.
Specifications 1.Main system part 2.A/D conversion resolution 16 Bit 3.Sampling ratio 200kHz 4.Analysis time 5-5000ms 5.Stimulating frequency 0.1-50Hz 6.Amplifier part 7.Four-channel 8.Sensitivity 0.05μ V-20mV/Grid 9.Earth noise EMG <= 4μ V(Vpp) 10.EP <=0.1μ V(Vpp) (1000 times in average) 11.Common-mode rejection ratio >= 100dB 12.50Hz Ban wave setting: 13.Upper limit for Filter-frequency 20kHz 14.Lower limit for Filter-frequency 1Hz 15.Gain amplifies 25 times-400000 times 16.Stimulator part 17.Constant current 0.2-100mA 18.Pulse width 50-1000μ S 19.Short circuit and overloading protection 20.Auditory Stimulator 21.Stimulation wave 40Hz Short, Sound Stim 22.Stimulation polarity nondense wave, dense wave and alternant wave. 23.Sound strength 40-120db (5db per level) 24.Stimulation mode left, right, left & right 25.Frequency of 40Hz carrier wave 500-8000Hz 26.Visual stimulator 27.Mode tessellation, horizontal bar and vertical bar. 28.Stimulation view all-view, half-view and quarter-view 29.Resolution 3x4, 6x8, 12x16, 24x32, 48x64 30.Flash stimulator all quench, left light, right light, l&r light
Accessories: 1. Disk 2. Power Cord 3. Power Adapter 4. USB Cable 5. Audio Cable 6. Earth Cable 7. Current Stimulator 8. One-off Bipolar Needle Electrode D039035408, 0.35*40mm, D039060706, 0.60*70mm 9. Reuseable Bipolar Needle Electrode R039035408, 0.35*40mm, R039060706, 0.60*70mm 10. Concentric Needle Connecting Wire 11.1mm Connecting Lead Wire 12. Disc Electrode 13. Ring Electrode 14. Surface Electrode 15. Ground Electrode(Include lead cable) 16. One-off Unipolar Needle Electrode 17. From 1 to 2 Conversion Cable 18. Surface Electrode Conversion Cable 19. Fuse 0.1A/250V, 5*20mm 20. Fuse F1.6AL250V, 5*20mm 21. Flash Stimulator 22. Audio Stimulator